FOUNDATION REPAIR

The anchor is spread apart enough to allow installation of the sill plate.  Also enough strap is left above the concrete to ensure that the sill plate can be correctly secured. 

The strap is pushed too far into the concrete and is not spread apart  for proper sill plate instalation.  The strap may  pull out under extreme loads.  

Check beam pockets prior to pouring concrete and after wall is stripped.          

Beam pockets not checked prior to pouring concrete.  Neither checked  nor centerline marked, the after wall was stripped.  

Always pick up all ground rods or wires before you leave the jobsite.  Tie up the copper wire to the wall

Always pick up all ground rods or wires before you leave the jobsite.  Tie up the copper wire to the wall

Safety issues – Beams are not stable. Beams can fall on carpenters during erection. The shims are not well placed under this beam

Additional steel shims are not available when carpenters are setting steel. No one orders 3 times the steel shims needed

2 x 2 nailers are to be placed into center of the window buck.   

If the nailers are placed too close to the edge of the window buck, then concrete will spall.   

All anchor clips should be 42” on center and 12” off each corner.                                                        

Anchor clips should be 12” off each corner and 42” on center.  Garage legs need 2 anchor clips. They are missing

Using your line, determine the correct height of your columns, no more than a couple o shims should be needed to reach elevation                                                    

Unacceptable !